CPAP and Bpap Bilevel Non-Invasive Ventilator

Product Details
Customization: Available
Type: Non-Invasive Ventilator
Used for: Adult, Child
Manufacturer/Factory, Trading Company
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
<100 square meters
  • CPAP and Bpap Bilevel Non-Invasive Ventilator
  • CPAP and Bpap Bilevel Non-Invasive Ventilator
  • CPAP and Bpap Bilevel Non-Invasive Ventilator
  • CPAP and Bpap Bilevel Non-Invasive Ventilator
  • CPAP and Bpap Bilevel Non-Invasive Ventilator
  • CPAP and Bpap Bilevel Non-Invasive Ventilator
Find Similar Products

Basic Info.

Model NO.
AC09
Transport Package
Carton
Specification
31*21*40cm
Trademark
Kindsway
Origin
China
HS Code
9019200090
Production Capacity
5000/Month

Product Description

SPECIFICATION

1. Work mode: CPAP / Auto CPAP
2. White/Blue LCD screen
3. Pressure:4-20cmH2O
4. Relax (1-3level): 2-4cmH2O
5. Sound pressure: <30db
6. Ramp duration: 0-60min

CPAP and Bpap Bilevel Non-Invasive VentilatorCPAP and Bpap Bilevel Non-Invasive Ventilator

Pressure 4~ 20cmH2O with a 0.5cmH2O increment
IPAP 4~ 20/25cmH2O with a 0.5cmH2O increment
EPAP 4~ 20/25cmH2O with a 0.5cmH2O increment
ISlop 1-6 level
Esens 1-6 level
BPM 4-40BPM
Insp Time 0.5-3.0s
Ramp 0 -60 min


Belex
  1. level Close Belex
  2. level setting pressure -2cmH2O 2 level setting pressure -3cmH2O
3 level setting pressure -4cmH2O




Humidifier
0 gear close the humidifier 1 level 45ºC
  1. level 50ºC
  2. level 55ºC
  3. level 60ºC
  4. level 65ºC
System time 24-hour
Backlight 30seconds,60seconds,90seconds,120seconds,150seconds,240sec
onds,330seconds,420seconds,510seconds,600seconds
 
Auto ON/OFF: When the Auto ON/OFF is set to "ON", user wears the mask and takes 3 breaths under the standby state, then the device will enter into working state; User takes off the mask under the working state,then within 15 seconds the device will enter into the standby state.When such function is set, the device will automatically enter into the standby state in case of the mask or tube falls off during the sleep.
RAMP: Setting pressure ramp duration function,the device works at a 4cmH2O output pressure at the beginning and increase stably to the setting pressure within the setting time. After this function is set, pressing the on/off button for the first time the device will start running with ramp function; and with the second pressing, the device will jump the ramp function and run at the setting pressure directly.
Working mode: There are four working modes(CPAP,S,T,S/T)
CPAP mode: The device outputs a constant pressure.
S(Spontaneous) mode: Trigger by spontaneous respiration of patient, automatically conversion between inspiration pressure and expiration pressure.
T(timed) mode: After setting the BPM(breath frequency per minute) and inspiration time, the device will automatically convert between inspiration pressure and expiration pressure according to the setting parameter.
S/T(Spontaneous/Timed) mode: the device works at S mode if the patient breath normally; the device will switch to T mode if the spontaneous respiration interval of patient exceeds the set respiratory frequency.
Pressure: Under Mode CPAP, the device outputs the setting pressure.
Belex: Setting the Belex function under the CPAP Mode,the device will automatically detect respiratory rhythm of the user and lower pressure in the mask during the expiration to make the user feel more comfortable.
IPAP: Inspiratory Positive Airway Pressure under S, T and S/T Mode
EPAP: Expiratory Positive Airway Pressure under S, T and S/T Mode
Islop: It depends the time of the pressure rising from expiration phase to inspiration phase under S, T and S/T Mode.The time for 1-6 gear are 600ms, 500ms, 400ms, 300ms, 200ms and 100ms; the larger the gear is, the short the time is.
Esens: It depends the trigger time of the switching from inspiration phase to expiration phase under S, T and S/T Mode.
InspTime: Under Mode T and S/T, length of inspiration time within one respiratory

cycle is set based on the inspiration time.
BPM: Under Mode T and S/T, the BPM(respiratory frequency) for the device to convert between inspiration pressure and expiration pressure
Humidifier: This controller turns the InH2 heated humidifier on/off and allows the heat setting to be adjusted
Date and time of the system: The device will take the record of patient information
Therapy Time: Total therapy time which can be reset
Use Time: Total use time which can't be reset.
Use Days: The device continuously work for more than 4hours is one day, and this time can't be reset.
CPAP and Bpap Bilevel Non-Invasive VentilatorCPAP and Bpap Bilevel Non-Invasive VentilatorCPAP and Bpap Bilevel Non-Invasive Ventilator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier