Type: Non-Invasive Ventilator
Used for: Adult, Child
Transport Package: Carton
Specification: 31*21*40cm
Trademark: Floton
Origin: China
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
ST-30
HS Code
9019200090
Production Capacity
100/Month

Product Description

ST30
BiLevel device with 5 modes of ventilation - S, T, ST, APCV and CPAP, inspiration pressure from
4cm H O to 30cm H O

 

SPECIFICATION

Dimensions 180 mm L×210 mmW ×105 mmH
Weight 1.6Kg (1.2Kg without humidifier)
IPAP range 4 -30 cmH2O (ST30)
EPAP range 4cm H2O - 20cm H2O
CPAP range 4cm H2O - 20cm H2O
Pressure accuracy ±(2% of the full scale reading + 4% of the actual read)
Ramp Time 0 - 60 min, 1min per step
Noise <30dB(A)(at 10 cmH2O/~1.0kPa)
Ventilation mode CPAP/S/ST/T/APCV
BPM (Backup rate) 5 - 50 bmp
Inspiratory time ratio(I/T %) 10% - 80%
Rise Time (ISLP) 1 - 6
ISNS 1 - 6
AUTO ON/OFF
Alarms Power failure, Leak, Apnea, Pressure, Mask OFF, Low
ventilation/Tidal volume
Monitoring parameters IPAP, EPAP, VTidal , Vminute ,BPM(RR), Leak
Compliance Meter 1st on operation, 2nd on breathing detection
Protection against electric shock Class II, EN 60601-1
Degree of protection against electric shock Type B applied part
Protection against water ingress Ordinary equipment, IPX1
Electromagnetic compliance EN 60601-1-2
AC/DC adapter Input: 100-240V, 50-60Hz, 2-1A; Output: DC24V , 2.5A
Operational Temperature +5ºC ~ +35ºC
Product certification CE 0123
Operational relative humidity 10% ~ 93% (non-condensing)
Operational Atmospheric pressure 700hPa - 1060hPa
Transport/storage temperature -20ºC ~ +55ºC
Transport/storage relative humidity 10% ~ 93% (non-condensing)
Transport/storage Atmospheric pressure 500hPa - 1060hPa
Accessories (Optional) Stand, Humidifier
Pressure control At the mask

Bilevel CPAP and Bpap Bilevel Noninvasive Ventilator Bipap Vpap
Bilevel CPAP and Bpap Bilevel Noninvasive Ventilator Bipap VpapBilevel CPAP and Bpap Bilevel Noninvasive Ventilator Bipap VpapBilevel CPAP and Bpap Bilevel Noninvasive Ventilator Bipap Vpap

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
<100 square meters