Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Mobile Digital Radiography DR System BTR-M400/MW400
Full digital x-ray detector system
Image acquisition and processing workstation
Mobile electric rack
High frequency X-RAY generator
Advanced image processing software
BTR-MW400 is a very intelligent mobile DR, provides abundant sweet operation functions, not only with humanized design and simple operation, but also the advantages as below:
1) Safe and reliable
2) Easy to move
3) Simple operation
4) Fast positioning
5) Oversize touchscreen
6) Storage battery
7) High performance industrial personal computer
8) Wide clinical applications
9) Smart design
l Safe and reliable
Considerate anti-collision design
Care for patients and passengers, protect the machine from damage.
S# |
Description |
Parameters |
BTR-MW400 mobile digital X-ray system |
Main functions and use: obtain images through X-ray system and digital flat panel detector, examine the whole body like chest, limbs, brain and abdomen at vertical position, clinostatism and for patients in wheelchair, get high resolution digitized imaging and auto imaging processing. |
|
1 | X-ray generator | |
1.1 | HF inverter H.V. generator | YES |
1.2 | Max. output power | 40kW |
1.3 | Max. tube voltage | 150kV |
1.4 | max. exposure time | 6300ms |
1.5 | Max. output mA | 400mA |
1.6 | Output range of mAs | 0.1mAs~500mAs |
1.7 | cable | 5.5m |
2 | X-ray tube | |
2.1 | Dual focus | YES |
2.2 | Focus specification | 0.6mm/1.2mm |
2.3 | Max. power of big focus | 50kW |
2.4 | Max. power of small focus | 22kW |
2.5 | Max. tube voltage | 150KV |
2.6 | Heat capacity | 150KHU |
2.7 | High speed rotating anode | YES |
3 | Movable frame | |
3.1 | Electric auxiliary drive | YES |
3.2 | Vertical rotating angle range | ±270º |
3.3 | Deviation of vertical rotating angle | ±2° |
3.4 | Stretchable arm | |
3.4.1 |
Vertical frame lifting range from tube center |
570mm~1800mm, ±5% |
3.4.2 | Stretching range from tube center | 710mm~1240mm, ±5% |
3.5 | ||
3.5.1 | Manual rotation | YES |
3.5.2 | Rotating range (X-Z) | ±180° |
3.5.3 | Rotating range (Y-Z) | -30°~90°, ±5° |
4 | beamformer | |
4.1 | Rotatable from tube axis | YES |
4.2 | Rotating angle range | ±90º |
5 | Flat panel detector | |
5.1 | Scintillator material | A-Si |
5.2 | Imaging area | 14''×17'' |
5.3 | Pixel size | 150μm |
5.4 | Image grey | 14bit |
5.5 | Pixel matrix | 2288×2800 |
5.6 | Max. spatial resolution | 3.4 lp/mm |
5.7 | Min. preview time | No more than 10s |
5.8 | Connecting method | Wireless |
6 | Image acquisition workstation | |
6.1 | Hard disc capacity | ≥1TB |
6.2 | Image storage capacity | No less than 40,000 images |
6.3 | DICOM-3.0 | YES |
6.4 | Barcode patient info. input | OPTIONAL |
6.5 | CPU | CORE I3 |
6.6 | Main frequency | 3.3GHz |
6.7 | Memory | ≥8GB |
6.8 | Image monitor | ≥19 |
6.9 | Display resolution | 1280×1024 |
6.10 | Max. brightness | 250CD/m2 |
6.11 |
Operation system |
Windows based Chinese & English interface, including patient registration, photography examination, image browsing, data management and transmission functions. |
7 | Software function | |
7.1 | Patient information display | YES |
7.2 | Edge enhancement | YES |
7.3 | Window width/level adjustment | YES |
7.4 | Dynamic range adjustment | YES |
7.5 | Image inversion | YES |
7.6 |
Multi frequency window / multi grey window imaging processing, improve image display dynamic range, insure clear contrast between high and low density area of images. |
YES |
7.7 | Auto image optimization processing per | YES |
anatomy part | ||
7.8 | |lage roam | YES |
7.9 | Image composition | YES |
7.10 | Network speed | 100MB/SEC |