Hospital Equipment Multi-Parameter Patient Monitor
Introduction
This Hospital equipment can monitor such parameters as ECG, RESP, NIBP, SpO2, PR and Dual- channel TEMP.CMS6800 Multi-parameter Paitent Monitor integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment.
-8'' color LCD with high-resolution displays patient parameter and waveform collected, and alarm, bed NO., clock, equipment state and other information provided by the monitor synchronously.
-Operation interface with 15 languages. Finish all operations by keys and knobs. (Optional languages: Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech.)
-Be applicable for monitoring adult, pediatric and neonate.
Features
1)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
2)Waveform, parameter color and location can be set optionally.
3)Finish all operations by keys and knobs.
4)Display 7-lead ECG waveform on one screen, cascade ECG waveform display
5)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
6)Heart rate variability (HRV) analysis function
7)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
8)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
9)Drug concentration calculation and titration table functions.
10)One-touch printing of trend graph
11)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
12)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
13)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary)
Specification
- Safety classification
Type of protection against electroshock: Class I
EMC: A
Degree of protection against electroshock: type CF defibrillation-proof applied part
Degree of protection against ingress of water: IPX0
- Environment requirement
Temperature:
Working: 5~40(ºC)
Transport and storage: -40~+55(ºC)
Humidity:
Working: 30%~75%
Transport and storage: ≤95%(no coagulation)
- Power supply
Power supply: AC100-240V, 50/60 (Hz)
Maximal input power: 150VA
- Display
Waveform: display 8-channel waveform in a screen
Resolution: 800 × 600
Color: waveform and parameter color can be set
Waveform and parameter selection: parameter and waveform need to be displayed can be selected, and waveform position also can be adjusted.
- Alarm
Alarm items: technical alarm, 71 physiological alarms and 60 arrhythmia alarms.
Prompt mode: visible and audible alarm (3 alarm levels)
- Trend review
Time: trend review for 480-hour, review for 2400 groups of BP data
Review mode: trend graph and trend table
SD card review: trend review and review for 72-hour ECG waveform
- Printer (optional)
Waveform: 2-channel
Print width: 48mm
Paper speed: 25mm/s, 50mm/s
- Battery
Working time: 150 minutes
- Updating mode
Software updating: network updating and U disk updating
- ECG
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVF, aVL, V
Gain: ×0.25, ×0.5, ×1, ×2
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and alarm range
Adult: 15~300bpm
Pediatric and neonatal: 15~350bpm
Accuracy : ±1% or ±1bpm, whichever is greater
ST segment monitoring:
Measurement and alarm range: -2.0mV~+2.0mV
Accuracy: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is greater
Arrhythmia analysis : 13-arrhythmia
Volume: 0~7
Pacemaker: yes
- RESPIRATION
Method: R-F(RA-LL) Impedance
Measurement and alarm range for RESP rate
Adult: 0~120rpm
Pediatric and neonatal : 0~150rpm
Accuracy: ±2 rpm
Apnea alarm : 10~40s
Scan speed: 6.25mm/s, 12.5mm/s, 25 mm/s
- NIBP
Method: Oscillometry
Measurement and alarm range:
Adult
Systolic: 40~270mmHg
Diastolic: 10~215 mmHg
Mean: 20~235 mmHg
Pediatric
Systolic: 40~200mmHg
Diastolic: 10~150 mmHg
Mean : 20~165 mmHg
Neonate
Systolic: 40~135 mmHg
Diastolic: 10~100 mmHg
Mean: 20~110 mmHg
Inflation time: <30s(10~270 mmHg, standard adult cuff)
Measurement time: <40s
Measurement interval in AUTO mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes
Accuracy for BP measurement: ±5mmHg, maximal standard deviation: 8mmHg
Over-pressure Protection:
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg
- TEMP
Temperature curve: YSI-400
Channel: dual-channel
Measurement Range: 0 ~ 50ºC
Accuracy: 0.1ºC
Display resolution: 0.1ºC
- SpO2
Measurement Range: 0 ~ 100 %
Measurement accuracy : 70%~100%: ±2%;
0%~69%: unspecified
Display resolution: 1%
Upper and lower limit for alarm: 0~100%
Measurement and alarm range for PR: 30~250bpm
Measurement accuracy for PR: ±2bpm or ±2%, whichever is greater.
Pulse modulation volume: yes
Physical characteristic
Dimension: 227 x 153x 247 (mm)(L×W×H)
Weight: 2.4kg
Accessories
- User Manual
- SpO2 probe extension line (5-pin)
- Adult fingertip SpO2 probe
- NIBP extension tube
- NIBP metal plugs
- Adult NIBP cuff
- ECG lead wire (American standard)
- ECG electrode
- Temperature probe
- Power cord