Hfnc High Flow Oxygen Therapy Nasal Cannual Ventilator

Type: Breath Therapy
Function: Oxygen Therapy
Theory: Oxygen
Certification: CE, ISO13485
LCD Display: Without LCD Display
Group: Adult
Samples:
US$ 1500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Name
Hfnc
Transport Package
Carton
Specification
13kg
Trademark
kindsway
Origin
China
HS Code
841989909
Production Capacity
500units/Month0

Product Description

HFNC High Flow Oxygen Therapy Nasal Oxygen Cannula Oxygen Therapy Machine


Advantages:

>Compared with the traditional oxygen therapy, the optimum humidity oxygen supply can be controlled.

>Easy to use and tolerate, and supply flow and oxygen concentration without any influence.

>When the patient was removed or changed, the treatment was variable and continuous.

>The interface is smaller and does not require a variety of devices and treatment interface switching.promote oxygenation, reduce WOB.

>Improve airway mucosal clearance, more comfortable.

>Reduce the dead space of the pharynx and provide low level positive pressure.

>Get the same effect as low level CPAP.

 

Consist of:

Air-oxygen blender;

Chamber with heated;

Breathing circuit with heated wire;

Nasal prong.

Choose to match: medical air compressor.

 

Technical parameter:

>Air-oxygen blender (AD3000-SPA)

 

»FiO2

21%~100%

»alarm noise

>57dB(A)

»Folw

0~18LPM »pressure of air       and oxygen 0.3MPa~0.4MPa

»gas-source             interrupted

audible alarm

»measurement of     main machine

6.8*6.8*7.5cm
»pressure difference Pressure difference more   than 0.1MPa, audible       alarm »weight About 1.6kg
»alarm time > 60s

»certificate

EN ISO 13485

 

>PN-2000FB humidifier

 

»temperature

Mode with Heated wire:          25ºC~39ºC

»Max-temp of          heating appliance

<85ºC
  Mode without heated    wire: 23ºC~37ºC »thermal cutoff of heating  plate 120±5ºC

»maximum water        capacity

230mL »operating ambient       temperature

18ºC~26ºC

»working pressure ≤2kPa »display window flashing patient distal               temperature>40ºC
»flow 180L/min »H patient distal               temperature≥50ºC
»drop of pressure <300Pa »L patient distal               temperature≤10ºC
»power supply 220VAC 50Hz »ER2 heating plate sensor    failure or off
»power              consumption 150W »ER3 heating plate sensor    failure or off
»volume 135mm*145mm*155mm »weight

3.2kg


Hfnc High Flow Oxygen Therapy Nasal Cannual Ventilator
Hfnc High Flow Oxygen Therapy Nasal Cannual VentilatorHfnc High Flow Oxygen Therapy Nasal Cannual VentilatorHfnc High Flow Oxygen Therapy Nasal Cannual VentilatorHfnc High Flow Oxygen Therapy Nasal Cannual Ventilator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
<100 square meters