Multi-Parameter Monitor (CMS9000) - CE&FDA

Product Details
Customization: Available
Classification: Biological Diagnostics
Type: Patient Monitor
Manufacturer/Factory, Trading Company
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
<100 square meters
  • Multi-Parameter Monitor (CMS9000) - CE&FDA
  • Multi-Parameter Monitor (CMS9000) - CE&FDA
Find Similar Products

Basic Info.

Model NO.
CMS9000
Certification
CE, ISO13485
Transport Package
Carton
Specification
ECG, NIBP, SpO2, Respiration, Temperature
Trademark
SANSHUN
Origin
China
HS Code
9018193010
Production Capacity
500/Week

Product Description

Model: CMS9000 
Features


- Color TFT Screen, waveform up to 8 channels
- Light and portable with build-in rechargeable battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
- 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo RMS.
- Built-in recorder(option)
- All-round monitor of adult, pediatric and neonatal.
- Electrosurgical unit and defibrillation protected
- Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
- Option parameters: EtCO2, CO, IBP, Thermal Printer

ECG

- 5-lead or 3-lead selectable
- Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
- Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL
- Gain selection: 12.5mm/s, 25mm/s, 50mm/s
- Accuracy: ± 1bpm or ± 1%, whichever is greater
- Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal: 1mV± 5%
- Operation modes: Diagnostic, Monitor, Surgery
- Alarm range: Adult: 15-300bpm
- Pediatric/Neonatal: 15-350bpm
- Alarm range: -2.0mV~2.0mV
- S-T detection: YES, Arrhythmia analysis: YES
- Alarm: YES, audible and visual alarm, alarm events recallable

NIBP

- Method: Oscillometry
- Operation modes: Manual/Automatic/STAT
- Measurement unit: MmHg/KPa selectable
- Measurement types: Systolic, Diastolic, Mean
- Measurement range: Adult: 10-270mmHg
- Over-pressure protection: YES
- Resolution: 1mmHg
- Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm: Systolic, Diastolic, Mean

SpO2

- Measurement range: 0-100%
- Accuracy: ± 2digit (70~100%);
- 0~69% unspecified
- Alarm range: 0-100%

Respiration

- Method: RA-LL impedance
- Pediatric/Neonatal: 6-150rpm
- Alarm range: Adult: 6-120rpm
- Pediatric/Neonatal: 6-150rpm
- Apnea alarm: YES

Temperature

- Resolution: 0.1
- Channel: Dual-channel
- Alarm range: 0-50
Option:

EtCO2

- Measurement Mode: Side-stream or mainstream
- Measurement range: EtCO2: 0-99mmHg
- Accuracy: CO2 concentration
- Apnea alarm: YES

IBP

- Channel: 2 channels
- Pressure transducer: Sensitivity: 5( mV/V/mmHg)
- Transducer sites: ART, PA, CVP, RAP, LAP, ICP
- Alarm range: -10~300mmHg
Standard six parameters ECG,SPO2,RESP,TEMP,NIBP,PULSE RATE
Optional ETCO2,CO,IBP,Thermal Printer
Screen size 12.1 inch
Size 310*140*263mm
Net Weight 3.8kg
Accessories 1) Adult SpO2 probe(5-pin)
2) Adult NIBP cuff
3) Extending tube for blood pressure
4) ECG lead
5) ECG electrode
6) Temperature probe
7) Power cord
8) Thermal recording paper(optional)
9) User Manual

Multi-Parameter Monitor (CMS9000) - CE&FDAMulti-Parameter Monitor (CMS9000) - CE&FDA

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier