Model: CMS9000 
Features


- Color TFT Screen, waveform up to 8 channels
- Light and portable with build-in rechargeable battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
- 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo RMS.
- Built-in recorder(option)
- All-round monitor of adult, pediatric and neonatal.
- Electrosurgical unit and defibrillation protected
- Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
- Option parameters: EtCO2, CO, IBP, Thermal Printer

ECG

- 5-lead or 3-lead selectable
- Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
- Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL
- Gain selection: 12.5mm/s, 25mm/s, 50mm/s
- Accuracy: ± 1bpm or ± 1%, whichever is greater
- Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal: 1mV± 5%
- Operation modes: Diagnostic, Monitor, Surgery
- Alarm range: Adult: 15-300bpm
- Pediatric/Neonatal: 15-350bpm
- Alarm range: -2.0mV~2.0mV
- S-T detection: YES, Arrhythmia analysis: YES
- Alarm: YES, audible and visual alarm, alarm events recallable

NIBP

- Method: Oscillometry
- Operation modes: Manual/Automatic/STAT
- Measurement unit: MmHg/KPa selectable
- Measurement types: Systolic, Diastolic, Mean
- Measurement range: Adult: 10-270mmHg
- Over-pressure protection: YES
- Resolution: 1mmHg
- Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm: Systolic, Diastolic, Mean

SpO2

- Measurement range: 0-100%
- Accuracy: ± 2digit (70~100%);
- 0~69% unspecified
- Alarm range: 0-100%

Respiration

- Method: RA-LL impedance
- Pediatric/Neonatal: 6-150rpm
- Alarm range: Adult: 6-120rpm
- Pediatric/Neonatal: 6-150rpm
- Apnea alarm: YES

Temperature

- Resolution: 0.1
- Channel: Dual-channel
- Alarm range: 0-50
Option:

EtCO2

- Measurement Mode: Side-stream or mainstream
- Measurement range: EtCO2: 0-99mmHg
- Accuracy: CO2 concentration
- Apnea alarm: YES

IBP

- Channel: 2 channels
- Pressure transducer: Sensitivity: 5( mV/V/mmHg)
- Transducer sites: ART, PA, CVP, RAP, LAP, ICP
- Alarm range: -10~300mmHg
Standard six parameters ECG,SPO2,RESP,TEMP,NIBP,PULSE RATE
Optional ETCO2,CO,IBP,Thermal Printer
Screen size 12.1 inch
Size 310*140*263mm
Net Weight 3.8kg
Accessories 1) Adult SpO2 probe(5-pin)
2) Adult NIBP cuff
3) Extending tube for blood pressure
4) ECG lead
5) ECG electrode
6) Temperature probe
7) Power cord
8) Thermal recording paper(optional)
9) User Manual

Multi-Parameter Monitor (CMS9000) - CE&FDAMulti-Parameter Monitor (CMS9000) - CE&FDA

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
<100 square meters