Measurement range 0-25 (MPa)
Structure: Single stage
How it works: Positive action
MEDICAL OXYGEN FLOWMETER FOR WALL
1. Application:
Medical device is connected with a medical gas distribution system, in order to adjust and measure the gas flow.
2. Model:
Table 1
Series |
Adapter/probe |
Flow range |
Remarks |
A |
|
A Series |
|
AS |
|
SIS /Australian |
|
1 |
|
1.5LPM |
|
200ml |
B |
|
B Series |
|
AGA |
|
Scandanavian |
|
2 |
|
3.0LPM |
|
170ml |
C |
|
C Series |
|
BS |
|
BS/ British |
|
3 |
|
6.0LPM |
|
300ml/Brass |
D |
|
D Series |
|
C |
|
Chemetron®-Style /USA |
|
4 |
|
8.0LPM |
|
200ml/Brass/Dual |
E |
|
E Series |
|
D |
|
DISS1240/USA |
|
5 |
|
10LPM |
|
170ml |
F |
|
F Series |
|
F |
|
AFNOR/French |
|
6 |
|
15LPM |
|
300ml/ Aluminum |
G |
|
G Series |
|
G |
|
DIN13260/Germany |
|
7 |
|
17LPM |
|
200ml/Medical cranes |
H |
|
H Series |
|
I |
|
UNIFOR/Italian |
|
8 |
|
30LPM |
|
250ml/ Aluminum |
I |
|
I Series |
|
J |
|
JIS/Japanese |
|
9 |
|
40LPM |
|
170ml/ Aluminum |
M |
|
M Series |
|
O |
|
Ohmeda®-Style/USA |
|
10 |
|
70LPM |
|
Clock -Style |
|
|
|
|
ZA |
|
SANS/South Africa |
|
|
|
|
|
|
3. Technical data:
- Standard: the medical devices directive 93/42/EEC
- ISO 15002-2008
- Gas type: Oxygen (O2) or Medical air(AIR)
- Inlet pressure: 4.0/5.0Bar(ISO)/50psi(USA)/0.3MPa(ASIA) Optional
- Connected adapter: Optional(Table 1)
- Connection screw thread: UNF9/16-18"/M12*1.25mm/G3/8-19"
- Capacity of humidifier: 170ml/200ml/250ml/300ml/400ml/500ml
- Flow rates: Optional (Table 1)
- Flow accuracy: 10% of full scale
- Operating temperature: 0-40ºC
- Remark: *Because of the standards of different countries, it has different models.*
4. Instruction for use
- Make sure the device is undamaged.
- Make sure the knob is shut.
MEDICAL OXYGEN FLOWMETER FOR WALL
- Connect the device on the wall outlet, in a vertical position.
- Make sure the knob is shut.
- Connect the device on the wall outlet, in a vertical position.
- Connect patient tube to the flowmeter or to the humidifier.
- Turn the front knob and select the flow rate to be administered with the scale(reading in the middle of the ball)
- It is recommended to remove any device from the gas supply when not used.
- Add the water to the water level of humidifier before each use.
- Suggest using the pure water, and change the water once a person.
- About the flow of oxygen, please follow the doctor's advice.
5. Symbols
USE NO OIL See instruction for use
6. Clean and disinfection
- Please pour the water empty after each use.
- The materials of Polycarbonate can autoclave at 134ºC.
- The lid cannot be put into the jar to autoclave, otherwise it may be broken.
7. Safety advice:
-Do not disassemble by yourself.
-Do not use oil.
-Do not block safety valve.
-Do not use when there is gas leakage.
-Do not use it near the fire and the static occasions.
-The oxygen is highly flammable and explosive gas, it is dangerous.
8. Transport and storage
- Please avoid shaking when it is in the process of transportation.
- Between 0 ~40ºC (between 32~104ºF) in a dry and clean place.
- Keep the device in its plastic bag as long as possible.
- Periodic inspection
- The warranty is one year, but it does not cover damages or accidents due to carelessness, misuse, bad supervision or maintenance.
- Expiry: 5 years