Basic Info.

Model NO.
AC09
Theory
Electrotherapeutics
Certification
CE, ISO13485
LCD Display
With LCD Display
Group
All
Screen
3.5 TFT LCD Display
Press
4--20
Weight
2.2kg
Transport Package
Carton
Specification
280*200*112mm
Trademark
Kindsway
Origin
China
Production Capacity
50000000pieces/Year

Product Description

Product Description

Medical CPAP Auto AC09 BipapMedical CPAP Auto AC09 BipapMedical CPAP Auto AC09 Bipap
Specification
Screen
3.5 Inch color TFT
User Interface
One key operation
Pressure
4-20cmH2O,auto adjusting
Accuracy
±0.5cmH20
Belex
2-4cmH2O, 3 levels adjustable, makes the expiration more comfortable
Ramp
0-60min
Auto switch off
Yes
Noise
<30dB(10cmH2O)
Leakage compensation
Yes
Altitude compensation
Yes
Titration
Yes,95th titration
Humidifier
0-5 level,water chamber separable
SPO2
Yes, Optional
Parameter monitor
Flow/Press/LK/BPM/SpO2(Optional)/PR(Optional)
Realtime Alarm
Power failure/Low voltage/Airway Block/High Leakage/humidifier failure/TF card full
Data download
FT card 8G
Data report
available
Self-diagnostic questionnaire
Yes, makes patient understand the potential breathing apnea by himself.
Net Weight
2.2kg, 280*200*112mm(Host+humidifier)
Gross Weight
(Host+Humidifier+Handbag+Mask,Tube,Power adapter,Filter,Extension connector)
Medical CPAP Auto AC09 BipapMedical CPAP Auto AC09 BipapMedical CPAP Auto AC09 BipapMedical CPAP Auto AC09 Bipap
Auto ON/OFF: When the Auto ON/OFF is set to "ON", user wears the mask and takes 3 breaths under the standby state, then the device will enter into working state; User takes off the mask under the working state,then within 15 seconds the device will enter into the standby state.When such function is set, the device will automatically enter into the standby state in case of the mask or tube falls off during the sleep.
RAMP: Setting pressure ramp duration function,the device works at a 4cmH2O output pressure at the beginning and increase stably to the setting pressure within the setting time. After this function is set, pressing the on/off button for the first time the device will start running with ramp function; and with the second pressing, the device will jump the ramp function and run at the setting pressure directly.
Working mode: There are four working modes(CPAP,S,T,S/T)
CPAP mode: The device outputs a constant pressure.
S(Spontaneous) mode: Trigger by spontaneous respiration of patient, automatically conversion between inspiration pressure and expiration pressure.
T(timed) mode: After setting the BPM(breath frequency per minute) and inspiration time, the device will automatically convert between inspiration pressure and expiration pressure according to the setting parameter.
S/T(Spontaneous/Timed) mode: the device works at S mode if the patient breath normally; the device will switch to T mode if the spontaneous respiration interval of patient exceeds the set respiratory frequency.
Pressure: Under Mode CPAP, the device outputs the setting pressure.
Belex: Setting the Belex function under the CPAP Mode,the device will automatically detect respiratory rhythm of the user and lower pressure in the mask during the expiration to make the user feel more comfortable.
IPAP: Inspiratory Positive Airway Pressure under S, T and S/T Mode
EPAP: Expiratory Positive Airway Pressure under S, T and S/T Mode
Islop: It depends the time of the pressure rising from expiration phase to inspiration phase under S, T and S/T Mode.The time for 1-6 gear are 600ms, 500ms, 400ms, 300ms, 200ms and 100ms; the larger the gear is, the short the time is.
Esens: It depends the trigger time of the switching from inspiration phase to expiration phase under S, T and S/T Mode.
InspTime: Under Mode T and S/T, length of inspiration time within one respiratory

cycle is set based on the inspiration time.
BPM: Under Mode T and S/T, the BPM(respiratory frequency) for the device to convert between inspiration pressure and expiration pressure
Humidifier: This controller turns the InH2 heated humidifier on/off and allows the heat setting to be adjusted
Date and time of the system: The device will take the record of patient information
Therapy Time: Total therapy time which can be reset
Use Time: Total use time which can't be reset.
Use Days: The device continuously work for more than 4hours is one day, and this time can't be reset.
 