Features:
Introduction to functional features and simple adjustment of all digital notebook ultrasonic diagnostic instrument:
Full digital notebook ultrasonic diagnostic instrument with high definition and rich functions: mainly used in heart, abdomen, Urology, gynecology and obstetrics, pediatrics, etc.
Powerful image post-processing function First class digital imaging technology makes the image clearer Convenient operation and strong endurance.
Intelligent menu, easy and fast man-machine dialogue.
The standard computer keyboard is adopted to make the operation and input process easier.
Laser carving backlight button is adopted, which is more beautiful and atmospheric.
ARM chip architecture, with more stable and powerful functions. 32 channel signal processing for richer and clearer images. 15inch 1024 * 768 resolution high-definition LCD screen. Dual probe activation socket, VGA interface, USB2.0 interface, VIDEO interface. Built in lithium battery with a range of 2.5 to 5 hours.
Introduction to the instrument:
First turn on the power switch at the lower left part of the instrument, and then press and hold the power key, and the instrument will automatically enter the operation interface.
First press: probe (probe selection key) to select the department or organ. The scanning conditions of each department or examination part are preset in the instrument. The following fine adjustments can be made according to the customer's habits.
1: TGC slide left and right to adjust the proximity Medium Far field signal;
2: Rotate gain to adjust the total image gain.
3: Rotate depth depth adjustment.
4: Adjust the focus position to adjust the clarity of the position to be scanned.
5: Adjust freq and adjust the emission frequency of the instrument to adjust the image. The higher the frequency, the finer the image, but the less the signal.
6: Suppress nolcan by adjusting the dynamic range Dr. spots on the screen Adjust the image fineness. The higher the value, the finer the image, but the less the signal richness.
7: Adjust the richness and brightness of image signal: menu to enter selection - other settings - gray scale brightness. It is recommended to adjust in the range of 11-16 under different light.
Probe frequency(MHz) |
3.5MHz |
6.5MHz |
7.5MHz |
Probe type |
Convex probe |
Intracavitary probe |
High frequency linear probe |
Probe model |
C1-5-2/60R/3.5MHz |
EC1-9-4/ 13R/6.5MHz |
L1-9-5/7.5MHz |
Detection depth(mm) |
≥220 |
≥40 |
≥50 |
Lateral resolution(mm) |
≤3(depth≤80) ≤4(80<depth≤130) |
≤2(depth≤30) |
≤2(depth≤40) |
Axial resolution(mm) |
≤2(depth≤80) ≤3(80<depth≤130) |
≤1(depth≤40) |
≤1(depth≤50) |
Blind spot(mm) |
≤5 |
≤4 |
≤3 |
Horizontal geometric position accuracy(%) |
≤15 |
≤10 |
≤10 |
Longitudinal geometric position accuracy(%) |
≤10 |
≤5 |
≤5 |
Slice thickness(mm) |
≤10 |
≤10 |
≤10 |
Perimeter and area measurement deviation(%) |
±20 |
±20 |
±20 |
M mode time display error |
±10 |
±10 |
±10 |
M mode distance display error |
±10 |
±10 |
±10 |