Bubble CPAP Treatment of Nasal-CPAP for Premature, Neonate, Infant to Children

Type: Breath Therapy
Function: Oxygen Therapy
Theory: Oxygen
Certification: CE, ISO13485
LCD Display: Without LCD Display
Group: Children
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AD-10
Name
Bubble CPAP
Use for
Infant
Transport Package
Carton
Specification
13kg
Trademark
kindsway
Origin
China
HS Code
841989909
Production Capacity
500units/Month

Product Description

Bubble CPAP Nasal continuous positive airway pressure


Advantages:

Bubble CPAP is a sort of special medical equipment for supporting of babies' breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies' WOB effectively, while keeping the autonomous respiration well.

 

 

Superiority:

Supply a safe and controllable FIO2;

Keep the FRC effectively;

Reduce infant's WOB;

Reduce the need of invasive mechanical ventilation;

Supply better warm and humid gas;

Reduce the occurrence rate of the CLD;

Improve the physical sighs, such as height, weight.

 

Matching solution of Medical Air Compressor:

Max exhausting pressure: 0.7MPa

Output pressure: 0.20MPa~0.30MPa

Flow: >25L/ruin

Noise: <52dB(A)

 

 

Performance parameter:

FIO2: 21%~100%

Flow: 0~18LPM

CPAP pressure: 0.3~1.0kPa(3~10cmH2O)

Water capacity of Generator: 500ml or more

Alarm:the differential pressure> 0.1MPa, sound alarm

 

 

Common parameter:

Pressure of oxygen and air: 0.3MPa~0.4MPa

Power: 220V AC 50Hz

 

 

Parts:

Matching with Medical Electric Respiratory humidifier(PN-2000F/FA)

Working temperature: 30ºC~37ºC

Max temperature of heating plate: 85ºC

Capacity of Chamber:280ml(F-Adult); 230ml(FA-Infant)

Max flow: 180L/min

Max working pressure: 2kPa

 

 

CPAP Generator:

1. It is easy to set the oscillating gas pressure from 3cmH2O to 10cmH2O through adjusting the CPAP pressure bar.

2. The automatic regulating mechanism of water-level ensure the constant CPAP pressure.

3. The dismountable chamber is very convenient.


Bubble CPAP Treatment of Nasal-CPAP for Premature, Neonate, Infant to Children

>PN-2000FB humidifier

 

»temperature

Mode with Heated wire:          25ºC~39ºC

»Max-temp of          heating appliance

<85ºC
  Mode without heated    wire: 23ºC~37ºC »thermal cutoff of heating  plate 120±5ºC

»maximum water        capacity

230mL »operating ambient       temperature

18ºC~26ºC

»working pressure ≤2kPa »display window flashing patient distal               temperature>40ºC
»flow 180L/min »H patient distal               temperature≥50ºC
»drop of pressure <300Pa »L patient distal               temperature≤10ºC
»power supply 220VAC 50Hz »ER2 heating plate sensor    failure or off
»power              consumption 150W »ER3 heating plate sensor    failure or off
»volume 135mm*145mm*155mm »weight

3.2kg