Introduction
CMS5100 Vital Signs Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately measured.
Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family.
Features
- Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
- Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
- Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
- Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
- With user-friendly interface.
- Display with 2.8'' (320×240) color TFT LCD and red and yellow highlight LED.
- Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.
- Unique Flash memory, storage for up to 2000 NIBP data and 78000 SpO2 data.
- Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.
Performance
- NIBP monitoring
-Measurement method: Oscillometry
-Measurement mode: manual/auto/continuous.
-Auto measurement interval: adjustable from 1 to 90 minutes.
-Resolution: 1mmHg.
-Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
-Self-check function.
-Overpressure protection: double protection for software and hardware.
Range
-Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg
-Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
-Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
Upper and lower limit of alarm
-Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg
-Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
-Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
- SpO2 monitoring
-Continuous real-time measuring.
-Adopt digital SpO2 technology, which has strong anti-interference capability.
-Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse -rate(PR) trend graph.
-Standard finger-clip probe for adult , binding probe for neonatal is optional.
- SpO2 Measuring
Range: 0%~100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
- Pulse Rate Measuring
Range: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
- Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
- Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Accessories
- A power cord
- A power adapter
- A SpO2 probe
- An adult NIBP cuff
- An extending tube for blood pressure