Quantum Health Analyzer Pulse Oximeter Simulator Sphygmomanometer Surgical Instrument

Classification: Simulator
Type: SpO2 Simulator
Certification: CE, ISO13485
Group: All
Warranty Period: 18 Months for Main Unit, 6 Months for Accessory
Transport Package: Carton
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
MS100
Specification
DC 3.6V~4.2V
Origin
China
HS Code
9018909011
Production Capacity
100 Units/Week

Product Description

Model:MS100


1.SpO2 Simulator is a kind of Separated SpO2 simulator, small and light.
2.This oximeter simulator can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.

Features:
1.Separated connection between simulator probe and host, operation and test are more convenient.
2.262K color and 320*240 TFT, adjustable brightness level.
3.Film key-press, makes the operation more comfortable.
4.Power with chargeable lithium battery, can display the charge information of battery.
5.Key volume, can open or close.

Main Functions:
1..Pulse rate and Oxygen saturation simulation;
2.Patient state simulation preset;
3.test the reaction time of device;
4.simulate the SpO2 and pulse rate under different amplitude;
5.test the performance of device under different interference source;
6.select different R-curve.
 
Main Parameters
SpO2 -Measuring range: 35%~100%
-Resolution: 1%
-Error: When SpO2 is 75%~100%, the error is the larger between ± 2% and ± P(P denotes the ---precision of the tested oximeter); When SpO2 is 74%~50%, the error is the larger between ± 2% and ± P; No define when SpO2 is less than 50%.
Pulse rate -Measuring range: 25bpm~250bpm
-Resolution: 5bpm
-Error: 1%± 1bpm
Amplitude -Measuring range: 0.000%~20.000%
-Resolution: 1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
Patient state
 
-24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
-Voltage:DC 3.6V~4.2V
-Power Supply:Voltage 3.7 rechargeable lithium battery × 1
-Battery working life:Charge and discharge no less than 500 times.


Accessaries
-A MS100 user manual
-A 5.0V adaptor
Quantum Health Analyzer Pulse Oximeter Simulator Sphygmomanometer Surgical InstrumentQuantum Health Analyzer Pulse Oximeter Simulator Sphygmomanometer Surgical InstrumentQuantum Health Analyzer Pulse Oximeter Simulator Sphygmomanometer Surgical InstrumentQuantum Health Analyzer Pulse Oximeter Simulator Sphygmomanometer Surgical Instrument

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
<100 square meters