SPECIFICATIONS
Model LH8800
Display 10.4" screen
Ventilation Mode
VCV/IPPV,PCV,V-SIMV,PSV,CPAP,BIPAP,SIGH,PEEP
Air Source O2: 0.32Mpa±0.6Mpa
Air: 0.32Mpa±0.6Mpa
Tidal Volume
20ml~2000ml
peak velocity 180 L/min
Breath time 0.3-6s
Pressure control 0-50cmH2O
Inspiratory trigger mode Pressure & Flow
Inspiratory pressure trigger
-20 cmH2O~0 cmH2O
Flow trigger
0~20L/min
Maximum safe pressure <125 cmH2O
Inspiratory rise time 0.1-2.0s
Sign pressure
0~35 cmH2O
I:E 10:1-1:10
Pressure range
10~60 cmH2O
PEEP 0-25cmH2O
apnea interval 10-60s
Oxygen concentration range
21%-100%
Advantage Design
Gas - Electricity separation design ensures safe operation
Wide application to adults, children
Exhalation valve can be disassembled and disinfected, which avoids cross-infection.
Seamless switching of invasive and non-invasive ventilation mode
High integrated modular design of the gas circuit greatly reduces gas leakage , gas loss of
system dead space and system compliance and responds rapidly.
Proportional valve with high speed and high precision sends air quickly and accurately,
which improves the man-machine synchronization, reduces the consumption of
additional respiratory power, provides patients with comfortable excellent breathing.
Intelligent identification of off tube, blocking and other conditions ensures the safety of
patients.
Optional: humidifier, medical air compressor.
Monitoring Function
VT, MV, FREQ, FiO2%, Paw, CL , Flow[L/min], Pa[kPa],Waveform
Alarm Function
Upper and lower airway pressure limit alarm
Gas pressure shortage alarm
Upper and lower minute ventilation volume limit alarm
Upper and lower tidal volume limit alarm
Respiratory rate alarm
Oxygen concentration alarm
Low battery alarm
Asphyxiation alarm
Battery Built-in high capacity battery can ensure the machine working continuously not less than1 hour
Power Source
AC:100V-240V 50/60Hz
Model | 900B (Standard Model) |
Display | 10.4 inch high visibility color TFT display |
Ventilation Mode | A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, SPONT MANUAL |
Minute Volume | Greater than or equal to 18L |
Back-up Power Supply | At least 4 hours |
Tidal Volume | Adjustable range: 20-1500ml, Display range: 0-2000ml |
Respiratory Rate | 1-99bpm |
Inspiratory/expiratory (I:E) ratio | 4:1-1:4 |
PEEP | 0-10cmH2O |
SIMV Rate | 1-20bpm |
Inspiratory Pressure Trigger | .-10-10cmH2O |
Trigger Sensitivity (flow) | 1-10L/m |
Inspiratory Plateau | Adjustable from 0-50% of inspiratory time |
Adjustable Oxygen Concentration | 45-100% Without air compressor |
Gas Supply Requirement | 280~600 kPa medical grade oxygen and compressed air supply |
Pressure Limit | 1.0kPa~6.0kPa |
Maximum Safe Operating Pressure | ≤6.0kPa |
Tidal Volume Alarm | Upper Limit: 10~2000ml, Lower Limit: 0~1800ml |
Airway Pressure Alarm | Upper Limit: 0.1~6kPa, Lower Limit: 0~5kPa |
Oxygen Concentration Alarm | Upper Limit: 22~100%, Lower Limit: 21~80% |