• Factory Price Double Channels Hospital Medical Lab Auto Infusion Syringe Pump
  • Factory Price Double Channels Hospital Medical Lab Auto Infusion Syringe Pump
  • Factory Price Double Channels Hospital Medical Lab Auto Infusion Syringe Pump
  • Factory Price Double Channels Hospital Medical Lab Auto Infusion Syringe Pump
  • Factory Price Double Channels Hospital Medical Lab Auto Infusion Syringe Pump
  • Factory Price Double Channels Hospital Medical Lab Auto Infusion Syringe Pump

Factory Price Double Channels Hospital Medical Lab Auto Infusion Syringe Pump

Classification: Imaging Diagnostic Equipment
Certification: CE, ISO13485
Total Injection: 0.1ml---9999.9ml(0.1ml Step)
Kvo Speed: 1m/H
Maximum Infusion Pressure: 150kpa
IP Classification: Ipx2
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
BYZ-810T
Transport Package
Carton
Specification
280mm(L)*255mm(W)*205mm(H)
Trademark
SANSHUN
Origin
China
HS Code
9018909911
Production Capacity
50000000pieces/Year

Product Description

Product Description

Factory Price Double Channels Hospital Medical Lab Auto Infusion Syringe PumpFactory Price Double Channels Hospital Medical Lab Auto Infusion Syringe PumpFactory Price Double Channels Hospital Medical Lab Auto Infusion Syringe Pump
           Specification
Model
BYZ-810T& BYZ-810TU
Infusion Rate
50(60)ml Syringe 0.1ml/h---999.9ml/h(0.1ml/h step) 
1000mh/h---1500ml/h (1ml/h step) 
30ml Syringe 0.1ml/h---900ml/h(0.1ml/h step)
20ml Syringe 0.1ml/h---600ml/h(0.1ml/h step) 
10ml Syringe 0.1ml/h---300ml/h(0.1ml/h step)
Rate Accuracy
Within±3%(after correct calibration)
Purge Rate
50(60)ml Syringe:1500ml/h 
30ml Syringe:900ml/h 
20ml Syringe:600ml/h 
10ml Syringe:300ml/h
Mechanical Accuracy
Within±2%
Bolus Rate
50(60)ml Syringe:1200ml/h 
30ml Syringe:720ml/h 
20ml Syringe:480ml/h 
10ml Syringe:240ml/h
Equipment Classification
Class I,intermal power supply,Type CF
Fuse
T2AH/250V,2pcs installed
Power Consumption
35VA
KVO Speed
1m/h
Audible and Visible Alarms
Occlusion,Equipment failure,Software Exception,Injection finish,Limited finished,Battery running out,Improperly installed
,Abnormal operation ect.
Occlusion
High 800mmHg±200mmHg(106.7kPa±26.7kPa) 
Medium 500mmHg±100mmHg(66.7kPa±13.3kPa) 
Low 300mmHg±100mmHg(40.7kPa±13.3kPa)
Total Injection
0.1ml---9999.9ml(0.1ml step)
Volume Limit
0.1ml---9999.9ml(0.1ml step)
Maximum Infusion Pressure
150kPa
Bolus Rate
50(60)ml Syringe:1200ml/h 
30ml Syringe:720ml/h 
20ml Syringe:480ml/h 
10ml Syringe:240ml/h
Power Source
100-240Vac,50/60Hz;Internal rechargeable Li battery,capacity³1800mAh,voltage=11.1V,4 hours backup time at the rate of25ml/h(appointed medium rate in IEC60601-2-24)for the new battery charged for 12 hours.To facilitate the use in some special
occasions,the machine's DC outlet can be an external DC 12V 2A standby power supply.
IP Classification
IPX2
Syringe
Compatible with 10ml,20ml,30ml,50/60ml syringe of any brands after correct calibration The following brands of syringe sets are
recommended:Dispovan,Romsons,BBRAUN,SHINVA
Syringe maximum value (under single fault condition)
1ml
Dimension
280mm(L)×255mm(W)×205mm(H)
Net Weight
3.6kg
Package Reference
1pc Carton:4.6KG,34cm(L)×32cm(W)×26cm(H) 
2pcs Carton:9.2KG,76cm(L)×30cm(W)×36cm(H)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now